Controlling Noise in Every Environment

  413.789.1770
  impacta@soundseal.com
Impacta VC-300 Acoustic Tests

vc300
2mm vinyl flooring over 3mm VC300 over 6" concrete slab-no ceiling
IIC50
VC1A-1
--------------------------
2mm vinyl flooring over 3mm VC300 over 6" concrete slab-no ceiling
Δ IIC 22 VC-2B
-----------------------
2mm vinyl flooring over 3mm VC300 over 1 ½” gypsum topping over 5/8" plywood - 16” TJI – 24 centers RC1 channel – batt insulation - 1 layer 5/8 GWB
IIC55 VC-4A
-----------------------
2mm vinyl flooring over 3mm VC300 over Metal frame construction 8" Dietrich TradeReady Floor Joist @ 24" o.c. - 9/16" metal form w/ 1 9/16" gypsum concrete, WAVE Suspended Drywall Ceiling Grid, 3-1/2" Fiberglass Batt Insulation, 1 Layer 5/8" Type C Gypsum Sheathing, + 1 Layer 1/2" Type X Gypsum Sheathing

FIIC 51 VC5-A

-----------------------
No flooring or underlay 10" concrete slab-no ceiling
FIIC 42  VC-6A

-----------------------
2mm vinyl flooring /no underlay over 10" concrete slab-no ceiling
FIIC 44 VC-6B

-----------------------
2mm vinyl flooring over 3mm VC300 over 10" concrete slab-no ceiling
FIIC 64    VC-6C 

-----------------------

Sound Seal | 50 H.P. Almgren Dr | Agawam MA | 01001 | 413.789.1770