Controlling Noise in Every Environment

  413.789.1770
  impacta@soundseal.com
Impacta RedUpax Acoustic Tests

 

redupax

Product Data:

  • Made from 100% natural wood fiber, allows for leveling of floor imperfections up to ⅛” per 3 ft.
  • Free-floating, economical underlay saves installation time
  • Rigid, stable top surface simulates the sound and feel of nail-down hardwood flooring.
  • Excellent thermal qualities for warmth and comfort
  • High smoothing qualities, creates a beautiful finished floor
  • Will not bounce like many foam & felt products, increases lifetime of the floor.
  • Removes the hollow sound attributed to many floated engineered hardwood and laminate floors

 

Impacta Redupax Acoustic Tests
Floated Laminate flooring over 9mm Redupax over 6"
concrete slab-no ceiling
IIC 52 RP-1A
-----------------------
Floated Eng. Hardwood over 9mm Redupax over 6" concrete slab- no ceiling
FIIC 60  RP-2B  
-----------------------
Floated Eng. Hardwood over 9mm Redupax over 1 ½” gypsum topping over 5/8" plywood -  16” TJI – 24 centers RC1 channel – batt insulation - 1 layer 5/8 GWB 
IIC 52 RP-1A
-----------------------
Floated Eng. Hardwood over 9mm Redupax over 1 ½” lightweight concrete topping over 5/8" plywood - 2 x 10" - 16" centers- batt insulation, RC-1 channel, 5/8" GWB
FIIC 55 RP-5A 
-----------------------
Floated Eng. Hardwood over 9mm Redupax over 1 ½”
lightweight concrete topping over 5/8" plywood - 2 x 10" - 16" centers- batt insulation, RC-1 channel, 5/8" GWB  
FIIC 57 RP-6A
-----------------------
Nailed down 3/4" solid hardwood over 3/4" plywood over 9mm Redupax over 10" concrete slab-no ceiling
FIIC 62   RP-7A

Sound Seal | 50 H.P. Almgren Dr | Agawam MA | 01001 | 413.789.1770